Пропустить навигацию
Anyone know what’s causing this flooring damage? 🏚️🌊
0:00 / 0:37

Anyone know what’s causing this flooring damage? 🏚️🌊

Anttsinc

51 тыс. подписчиков

Открыть в X
279 отметок «Нравится»СкачатьОригинальный пост

155 877 просмотров

Anyone know what’s causing this flooring damage? 🏚️🌊 I just left a foreclosed home that’s been sitting vacant for 9 to 12 months. The previous owner invested a ton of money into high-end real wood flooring, but right now it's completely ruined. It’s buckling into massive waves, lifting off the subfloor, and literally disintegrating in one section. Here is the absolute mystery: The water is completely off in this house. 🚰❌ With no active running water or plumbing leaks, how does this happen? Is it a hidden slab leak coming up through the concrete, or did the brutal Texas humidity get trapped inside a sealed house with zero AC airflow for a year and rot the wood from the inside out? Calling all contractors, inspectors, and flooring experts. What’s your theory? Drop it in the comments below. 👇

43 комментария

Комментарии из оригинального поста в X (Twitter)

  • Фото профиля Are we there yet?

    @Brookwood5D

    That's engineered wood/flooring (plywood core and veneer). Solid wood floors would not react that way. Bad install, sh*t material and no climate control is what it appears to be.

    136 отметок «Нравится»

  • Фото профиля Patrick

    @patricksp71

    No subfloor probably put the wood floors right on the concrete and the wood just sucks any moisture from the concrete

    118 отметок «Нравится»

  • Фото профиля John Cialdella

    @jcialdella1

    Most likely trapped Texas humidity in a sealed house with zero AC for 9–12 months 🥵💨 Wood absorbs that moisture like a sponge and has nowhere to expand except UP 📈🏚️ Classic “greenhouse effect.” Hidden slab leak possible, but the widespread waves scream ambient humidity over a single leak.

    92 отметки «Нравится»

  • Фото профиля Nick Oliver

    @LancasterLumber

    Humidity is likely. Is the AC running?

    66 отметок «Нравится»

  • Фото профиля Anttsinc

    @anttsinc

    No water, no electricity on this one

    11 отметок «Нравится»

  • Фото профиля Nick Oliver

    @LancasterLumber

    The humidity in that house is probably tired of the humidity w/ no AC in TX.

    35 отметок «Нравится»

  • Фото профиля Krioklys

    @MysticSeer100

    When you lifted that board, you can see the crumbling of the underlying particle board. It's probably engineered flooring. Whether it's on a poorly protected slab could be another issue. Bottom line is that a solid hardwood floor is 3/4" and would have weathered the hot closed up environment better. Even if it buckled somewhat, conditioning the air and resanding it would have been fine. That engineered floor? Replace it. I'm not even a pro, just common sense and some experience.

    45 отметок «Нравится»

  • Фото профиля Jared

    @NoMarginGuy

    This is why you don't turn off HVAC in vacant properties to 'save money'.

    31 отметка «Нравится»

  • Фото профиля EvilMidget

    @Anniebanananie1

    That looks like water damage. Check spigots on outside and laundry hookups that they aren’t weeping onto the foundation

    16 отметок «Нравится»

  • Фото профиля Anttsinc

    @anttsinc

    Water to the home is completely turned off

    8 отметок «Нравится»

  • Фото профиля EvilMidget

    @Anniebanananie1

    Agree with others, likely humidity build up from sweating concrete. There’s a barrier sheet under that flooring likely making it worse

    24 отметки «Нравится»

  • Фото профиля wallstreet1929

    @wallstreet1929

    my vote - without an active HVAC system running to dehumidify the interior, ground moisture migrates up through the slab, gets trapped beneath the wood, while ambient air humidity saturates the top. The wood swells until the tension forces the floor upward.

    11 отметок «Нравится»

  • Фото профиля Cody

    @Designed2Think

    Sneaky moisture somewhere or poor installation that skipped leaving a gap for expansion and contraction.

    11 отметок «Нравится»

  • Фото профиля Good Shepherd Nika

    @TheGoodShep45

    Would think they would’ve known to install a vapor barrier on top of the concrete slab but you never know these days.

    10 отметок «Нравится»

  • Фото профиля KC

    @karibooloo_

    I had this exact flooring. You have to let it sit out and climatize (get used to the environment?) for a certain amount of time before install. They told us that when we bought it. You also have to leave a small space around the edges of the room for it to expand

    7 отметок «Нравится»

  • Фото профиля Oilfield Trash1960

    @trash196053474

    Vapor barrier under the slab is crap and they didn't seal the concrete before laying it down. Pull the wood and I bet you will see chalky whiteness from the water coming up. There is also a chance that they put the wood down before the slab was dry. Concrete normally dries at an inch a month from wet.

    7 отметок «Нравится»

  • Фото профиля Shea

    @SheaShea84283

    Is the air conditioning on?

    6 отметок «Нравится»

  • Фото профиля Anttsinc

    @anttsinc

    They refused to pay for the power, electricity

    5 отметок «Нравится»

  • Фото профиля Shea

    @SheaShea84283

    Sorry to post again. But looking at the flooring again, it’s not “real” wood. It looks to me like higher end plank flooring but not wood

    13 отметок «Нравится»

  • Фото профиля 🌀brenda_v71🌀

    @brenda_V71

    No moisture barrier btw the cement subfloor & the wood PLUS whoever laid that floor didn’t leave room enough for expansion and shrinkage, depending on humidity and weather.