Anyone know what’s causing this flooring damage? 🏚️🌊
51 тыс. подписчиков
155 877 просмотров
43 комментария
Комментарии из оригинального поста в X (Twitter)

@Brookwood5D
That's engineered wood/flooring (plywood core and veneer). Solid wood floors would not react that way. Bad install, sh*t material and no climate control is what it appears to be.
136 отметок «Нравится»

@patricksp71
No subfloor probably put the wood floors right on the concrete and the wood just sucks any moisture from the concrete
118 отметок «Нравится»

@jcialdella1
Most likely trapped Texas humidity in a sealed house with zero AC for 9–12 months 🥵💨 Wood absorbs that moisture like a sponge and has nowhere to expand except UP 📈🏚️ Classic “greenhouse effect.” Hidden slab leak possible, but the widespread waves scream ambient humidity over a single leak.
92 отметки «Нравится»

@LancasterLumber
Humidity is likely. Is the AC running?
66 отметок «Нравится»

@anttsinc
No water, no electricity on this one
11 отметок «Нравится»

@LancasterLumber
The humidity in that house is probably tired of the humidity w/ no AC in TX.
35 отметок «Нравится»

@MysticSeer100
When you lifted that board, you can see the crumbling of the underlying particle board. It's probably engineered flooring. Whether it's on a poorly protected slab could be another issue. Bottom line is that a solid hardwood floor is 3/4" and would have weathered the hot closed up environment better. Even if it buckled somewhat, conditioning the air and resanding it would have been fine. That engineered floor? Replace it. I'm not even a pro, just common sense and some experience.
45 отметок «Нравится»

@NoMarginGuy
This is why you don't turn off HVAC in vacant properties to 'save money'.
31 отметка «Нравится»

@Anniebanananie1
That looks like water damage. Check spigots on outside and laundry hookups that they aren’t weeping onto the foundation
16 отметок «Нравится»

@anttsinc
Water to the home is completely turned off
8 отметок «Нравится»

@Anniebanananie1
Agree with others, likely humidity build up from sweating concrete. There’s a barrier sheet under that flooring likely making it worse
24 отметки «Нравится»

@wallstreet1929
my vote - without an active HVAC system running to dehumidify the interior, ground moisture migrates up through the slab, gets trapped beneath the wood, while ambient air humidity saturates the top. The wood swells until the tension forces the floor upward.
11 отметок «Нравится»

@Designed2Think
Sneaky moisture somewhere or poor installation that skipped leaving a gap for expansion and contraction.
11 отметок «Нравится»

@TheGoodShep45
Would think they would’ve known to install a vapor barrier on top of the concrete slab but you never know these days.
10 отметок «Нравится»

@karibooloo_
I had this exact flooring. You have to let it sit out and climatize (get used to the environment?) for a certain amount of time before install. They told us that when we bought it. You also have to leave a small space around the edges of the room for it to expand
7 отметок «Нравится»

@trash196053474
Vapor barrier under the slab is crap and they didn't seal the concrete before laying it down. Pull the wood and I bet you will see chalky whiteness from the water coming up. There is also a chance that they put the wood down before the slab was dry. Concrete normally dries at an inch a month from wet.
7 отметок «Нравится»

@SheaShea84283
Is the air conditioning on?
6 отметок «Нравится»

@anttsinc
They refused to pay for the power, electricity
5 отметок «Нравится»

@SheaShea84283
Sorry to post again. But looking at the flooring again, it’s not “real” wood. It looks to me like higher end plank flooring but not wood
13 отметок «Нравится»

@brenda_V71
No moisture barrier btw the cement subfloor & the wood PLUS whoever laid that floor didn’t leave room enough for expansion and shrinkage, depending on humidity and weather.
6 отметок «Нравится»