don’t use CCA cables

383,016 görüntüleme • 7 ay önce •via X (Twitter)

40 Yorum

TracketPacer profil fotoğrafı
TracketPacer7 ay önce

so first of all, you can read all about the signal degradation & safety risks by googling this or looking at fluke networks’ write ups. also, have you heard of fire codes? if your building catches fire for any reason, clearly CCA cables will worsen the issue. this is why they’re illegal to install. skin effect is moot here. again, easily googleable. POE will cause heat which will lead to quick degradation of aluminum wire. once again—against spec for a reason. fire hazard. and overall signal degradation regardless.

Auto Nix Of The Seventh And Ninth Circles profil fotoğrafı
Auto Nix Of The Seventh And Ninth Circles7 ay önce

@TracketPacer Well you sure sounded like it in your first comment. They you got all moody and sad because she knows what's up and you don't even understand fire codes lol.

Auto Nix Of The Seventh And Ninth Circles profil fotoğrafı
Auto Nix Of The Seventh And Ninth Circles7 ay önce

@TracketPacer "Scientology nazi-like fire codes." In what world is any of this relevant, important or true? Never mind, I'm sure I don't want to know.

Artificial Shitposting Intelligence profil fotoğrafı
Artificial Shitposting Intelligence7 ay önce

dont use aluminum because the plastic jackets were different materials what kind of logic is this

International Cyber Digest profil fotoğrafı
International Cyber Digest7 ay önce

Whoever sells this kind of cable should be put in jail tbh.

gaussie profil fotoğrafı
gaussie7 ay önce

IN OUR DATA CENTER WE CALL FIRES UH OHS

Nathan Ambrose Barry profil fotoğrafı
Nathan Ambrose Barry7 ay önce

For science I want to see max POE in a stressed setup of a bundle of these (zip tie pinches, kinks, bundles all at 100w) and see if it ignites/how hot it gets.

TracketPacer profil fotoğrafı
TracketPacer7 ay önce

will do my best 🫡 at the very least i’ll be doing cable tests with it vs the real copper stuff

Nathan Ambrose Barry profil fotoğrafı
Nathan Ambrose Barry7 ay önce

You’re doing fantastic work. As a former rack and stacker I love attention to this physical layer stuff. I STILL hate some manufacturers that seemed to sharpen their rails to razor blades or have SFP pull tabs that ripped off.

mRr3b00t profil fotoğrafı
mRr3b00t7 ay önce

😅🤣🤣🤣🤣❤️🔥

Hans profil fotoğrafı
Hans7 ay önce

If you buy cheap on Amazon you are buying CCA cables. Looking at you MONKcables. What Amazon is allowing on their platform should be illegal.

Dinidu Perera profil fotoğrafı
Dinidu Perera7 ay önce

On the upside, CCA makes a great fuse for new year's or 4th of July shenanigans.

William Shipley profil fotoğrafı
William Shipley7 ay önce

This looks like a poor choice of wire coating. Plenum rated cable, whether CCA or solid/stranded copper, should only smoke a little, and not burn, when exposed to flame. Not all ethernet cables are plenum rated. (most patch cables have no requirements beyond UL 1685, because they're not permanent installs, which allows up to 8 feet of vertical flame propagation.) solid aluminum doesn't burn *at all* unless you get it very hot with a high surface area (eg powdered and dispersed in air), and if you were seeing that the flame would be extremely bright and hot, like a magnesium fire. It would also melt. Your wire is staying solid, so it's only the coating burning.

Tib3rius profil fotoğrafı
Tib3rius7 ay önce

Lmao.

BA14 profil fotoğrafı
BA147 ay önce

PVC smoke from a fire is kinda nasty, in a plenum it can be deadly

Greg Kutzbach, CISSP profil fotoğrafı
Greg Kutzbach, CISSP7 ay önce

A lot of structured cable is laid by non certified low voltage companies who find ‘cheap boxes of cat6’… which is this cca garbage. Would love to see you run some certifier tests and performance tests on copper vs cca cat 6 . Particularly of longer lengths.

Sadrian profil fotoğrafı
Sadrian7 ay önce

That's why the code says to use plenum for indoors applications. Duh!

Kellen profil fotoğrafı
Kellen7 ay önce

Not to mention CCA cable is a PAIN to work with. Give me copper or give me death.

Canadian Republic 🇨🇦 profil fotoğrafı
Canadian Republic 🇨🇦7 ay önce

How easy is it to run into this CCA stuff? Never heard of this being a thing.

d1ngbat profil fotoğrafı
d1ngbat7 ay önce

Someone on this planet cut corners and ran that shit through their whole building.

Pete Gibson, Union Printer profil fotoğrafı
Pete Gibson, Union Printer7 ay önce

Oh cool a new horror to see all around me

Mikey G. profil fotoğrafı
Mikey G.7 ay önce

Ok so you don't know the difference between riser and plenum cable.

A Fucking Leaf profil fotoğrafı
A Fucking Leaf7 ay önce

you striped the jacket off the end of the copper and then act surprised when you light the jacket on fire of the CCA because you didnt strip it. extremely disengenious video

LogitWorx profil fotoğrafı
LogitWorx7 ay önce

Just cut through the wire and see the silver color inside. But thanks for someone finally calling it fake. This stuff is everywhere! And none dare call it fake wire. This stuff has been causing automobile fires because the resistance is too high.

Calvin Robertson profil fotoğrafı
Calvin Robertson7 ay önce

Were those both Riser grade or Plenum grade? Very frightening if so.

Robert McLaws profil fotoğrafı
Robert McLaws7 ay önce

@Chris123NT That used to be the difference between Plenum and not Plenum back in the day, IIRC.

ibcryptox profil fotoğrafı
ibcryptox7 ay önce

One is old analog phone wire, the other digital CAT cable. The intended use dictates the type. Moe! Read a book.

GenXonX profil fotoğrafı
GenXonX7 ay önce

One is plenum rated one is riser rated. It’s normal, and you can certify both of them with a proper fluke versiv tester to the TIA/EIA spec.

LabRat Knatz profil fotoğrafı
LabRat Knatz7 ay önce

Looks like riser/plenum rated cable vs. plain ole PVC-insulated (which, almost all cheap CCA ethernet cables use). Admittedly, unoxidized aluminum is quite reactive. -I've heard stories from ISP techs about bunched CCA lines *exploding* from moisture-penetration and shorting.

𝐁𝐒𝐏𝟑 profil fotoğrafı
𝐁𝐒𝐏𝟑7 ay önce

Always make sure your cables meet specification. Generally, if Bluejeans Cable sells it, I buy it from them. That dude doesn't mess around. Everything meets specification, and installation rating is right on the page. He tries to get as much done in the US as possible.

N Ironwolf profil fotoğrafı
N Ironwolf7 ay önce

I feel like the fire demo is more about if it's CL-2 rated for plenum vs the stuff that's allowed in walls and places where when it burns it's not being poor in the air supply. 🤷‍♂️

TracketPacer profil fotoğrafı
TracketPacer7 ay önce

i can’t keep replying to the same shit over and over omfg yes the plenum matters but did you not see the damn wire actually catch? and the fact that afterwards it’s just cooked part of this is “it’s dangerous,” part of it is “this is how you tell them apart”

Doderic Dankenstein profil fotoğrafı
Doderic Dankenstein7 ay önce

They're getting harder to avoid I hate them

RealistSec profil fotoğrafı
RealistSec7 ay önce

Bruh, that's the 2-in-1 deal. Cables by day, PoE remote firework ignition cable by night 👀

A N profil fotoğrafı
A N7 ay önce

Half the price but double the cost...

Boris profil fotoğrafı
Boris7 ay önce

love to cheap out and destroy the fire barriers of the building i’m in but holy shit

Flynn, Resident Irritable profil fotoğrafı
Flynn, Resident Irritable7 ay önce

DUDE.

edward, the  ☠. profil fotoğrafı
edward, the ☠.7 ay önce

the sheath catching on fire has nothing to do with the conductor, and just getting copper conductors doesn't tell you that the sheath/jacket is proper materials.

Richard Watkins profil fotoğrafı
Richard Watkins7 ay önce

This is really important, Fire is a real risk and the smoke from cheap cable kills. Thats why Plenum cable and cable ratings is a thing, 👍

Anno Nymous profil fotoğrafı
Anno Nymous7 ay önce

Too many variables, bad comparison, first had a lot of exposed metal allowing more heat conductance along length of wire and was held in coolest part of the flame. Second wire had no metal exposed meaning all heat went to the insulation and it was held in hotter part of the flame