Flat Roof Polyurethane Insulation and Felt Waterproofing
524,709 Aufrufe • vor 1 Jahr •via X (Twitter)
11 Kommentare

Why are the insulation sheets not fixed? If there's any wind suction, they'll lift straight up

It takes over 6,000 nails to properly secure a roof. Even one out of place can lead to leaks or void a wind warranty. That’s why we patented the industry’s first larger nailing area, called The Zone®. #FeatureFriday #Weatherproof @Holcim

not safe at all in case of fire...

Protects from leaks & water damage

Sure

Never seen them use foam blocks like that. Probably great insulation

Looks like a fire hazard

A few notes: - insulation is Polyisocyanurate - insulation was not mechanically fastened or adhered (no wind uplift resistance) - no protection board over insulation prior to 1st layer of membrane (1st layer of membrane loose laid? - only one layer of membrane flashing at parapet and does not go up and over parapet (parapet not sloped to roof) - no UV protection on 2nd membrane layer Good technique installing membrane flashing (applied heat and pressure throughout and ensured bleed at seams)

Why damaging the blocks, what an amateur !

I thought that was Giant Tiramisu 😭

where is the foam between the blocks?