How to install an outside tap like a pro!
0:00 / 1:30

How to install an outside tap like a pro!

Arcfunmi

210K followers

Visit on X
2,979 likesDownloadOriginal post

795,447 views

How to install an outside tap like a pro!

35 Comments

Comments from the original post on X (Twitter)

  • Greg the tileman's profile picture

    @Gregthetileman

    Needs more Teflon tape

    90 likes

  • 🟧ELJAYGEE🇦🇺🦘's profile picture

    @Leon_Gallaher

    A pro wouldn't blast out a chunk of the inside wall! 🤣

    61 likes

  • Rico's profile picture

    @Boss351Tx

    Not enough thread tape 😂

    30 likes

  • 🦅🇺🇲BootLegger🇺🇲🦅's profile picture

    @Boot_Legger32

    Are those pro press fittings? Not supposed to solder them. Everything shown in this video is wrong.

    20 likes

  • Frank Robertson's profile picture

    @FrankRo52456258

    Maybe a pro would've used a core bit instead of a hammerdrill bit to blow out the inside of the wall, and just a fraction of the teflon tape? And here, you must use a self draining (freeze proof) faucet. But the workmanship itself looked good, even the disco light level.

    19 likes

  • Keith Colson's profile picture

    @KeithColson

    You should always slope the pipe down towards the outside of the house so leaks from the tap or rain will not drain inside. Big fail here.

    6 likes

  • sean wolf harper's profile picture

    @WolfSean57929

    If I would have done that as an apprentice, I would have never worked a day after that again. Yeah, no I don't know where that's called professional. that might be professional homeowner

    6 likes

  • AGP's profile picture

    @algo895

    Soldering pro press fittings?

    4 likes

  • Tired's profile picture

    @tiredortired

    Why do you post this slop? Last time everyone pointed out how fucking stupid this is inching blowing out the plaster and no angle. But then I checked and see you’re another Nigerian slop poster.

    4 likes

  • Mike's profile picture

    @micloben

    Sodders pro press fittings lol

    4 likes

  • Peppino. 🍀's profile picture

    @peppino3105

    Pour moi il n'y a que ce système qui serait valable, tu laisse la pression de de l'eau en permanence même par très grand froid sans risque de gel du robinet. Tu me remercieras plus tard.

    3 likes

  • ian furlong's profile picture

    @3countyheating

    Well, I’m glad you didn’t install that at my house. Didn’t see the plastering skills on the inside or a check valve.😳

    2 likes

  • jh0921's profile picture

    @jh0921261735

    Holy shit, I hope that was enough tape!

    2 likes

  • Sam U's profile picture

    @demanucan

    The hole in the wall. 😭 Very professional.

    2 likes

  • cuseGTO's profile picture

    @tfreyguy

    I have never in my life put a level on a copper pipe. Have I've been doing it wrong all these years

    1 like

  • Harry Willcock's profile picture

    @RICHARD21001377

    How do we drain down in winter to prevent the section through the wall from freezing?

    1 like

  • August Smith's profile picture

    @August_R_Smith

    Next winter with freeze can come.

    1 like

  • rRr 🇸🇰's profile picture

    @GromashHells

    If you see someone using LED powered level like that, you can be certain of one thing: he is NOT a pro! More like clown..

    1 like

  • Baudouin 1er's profile picture

    @ludovicbaudoin5

    Un pro qui a ruiné le mur à l’intérieur en perçant 👍👍👍😂😂😂😂tu parles d’un pro guignol

    1 like

  • BrightAF's profile picture

    @BrightAsF_ck

    Fucking hell... That rendering blow-out on the internal wall, I thought this was a parody!

    1 like