Inspector Failed My Final Inspection😯👷

221,006 views • 4 months ago •via X (Twitter)

35 Comments

mcfly85's profile picture
mcfly854 months ago

those straps are the least of your problems in this build

Second Sight's profile picture
Second Sight4 months ago

You have build 200 stairs wrong

FUGIO1787WEAREONE's profile picture
FUGIO1787WEAREONE4 months ago

Thank god you didn’t build anything for me, family, or friends.

Sameer Munawar's profile picture
Sameer Munawar4 months ago

Every hole in those straps needs a nail manufacturer spec, no shortcuts on stairs. Inspector did the job right. Fill 'em all next time.

4ev0er9's profile picture
4ev0er94 months ago

Ummmmm seriously 🤔?the stringer should butt up against the header. And rest into a hanging bucket..

MickM1911's profile picture
MickM19114 months ago

The size of that knot in the stringer is also questionable

DawktorX's profile picture
DawktorX4 months ago

200 bad decks. That hole is there for a reason lol

Not So Wild Anymore Bill's profile picture
Not So Wild Anymore Bill4 months ago

I would hypothesize that adding nails there is bound to split the wood and possibly detract from the overall joint strength. I've had my fair share of run-ins with inspectors that only count fasteners.

Randall T...'s profile picture
Randall T...4 months ago

4 Problems here: No nails in some holes. Knot and dark striations compromise integrity. Used hacksaw to cut wood? Pakistani account.

Nick Werner's profile picture
Nick Werner4 months ago

Will it work, yeah. Will it pass, no. The difference is liability, the manufacturer states every hole gets filled. If he passes a build with one missing, then the inspector assumes liability.

James Delgado's profile picture
James Delgado4 months ago

If an inspector says it needs a nail to pass his inspection… put a fucking nail there and quit your bitching.

Frizzman DeFryguy's profile picture
Frizzman DeFryguy4 months ago

as a deck builder of over 30 yrs, thats a def shit job and deserved to fail. that is not how steps are constructed

Nigel Hutton's profile picture
Nigel Hutton4 months ago

Yeah not the right strap, Needs a Ledger and a hanger

ΙΙঝীهقⱭ's profile picture
ΙΙঝীهقⱭ4 months ago

You know full well all nail holes in a hanger, need a nail to pass.

Russ's profile picture
Russ4 months ago

When there is disagreement, pull the code, look at the manufacturer’s instructions. If plans were drawn and sealed by a licensed engineer there should be details showing installation as well. If all requirements are followed then inspection should pass.

PNW LSR's profile picture
PNW LSR4 months ago

Obviously you didn't use every hole as specified by manufacturer and if you weren't such an ass, the inspector would have said put a nail in it, send me a picture, and ill pass it. Just like every inspector I've dealt with. Respect goes a long way.

Victor's profile picture
Victor4 months ago

I'd just nail a 2x8 to the beam over the straps as a hanger. That should satisfy the inspector.

Jack's profile picture
Jack4 months ago

Not the way I'd do it.

Nine Iron's profile picture
Nine Iron4 months ago

Those stringers could almost be upside down. Top of the stringer should be resting on the header or platform. Looking at how the top was cut it should have framed directly into the header with a bucket at a minimum

Brad Arnold's profile picture
Brad Arnold4 months ago

Inspector has no engineering skills apparently, bc those straps aren't going to break, or move as they are.

Nathan's profile picture
Nathan4 months ago

Put a nail in it then

GHOST__194's profile picture
GHOST__1944 months ago

Just put the nail in. Stop complaining

crispy's profile picture
crispy4 months ago

Surprised you haven't killed someone yet.

tom hagen's profile picture
tom hagen4 months ago

Shitty detail to start with.

hzhsjhdvbsh's profile picture
hzhsjhdvbsh4 months ago

Stringer should be resting on top of solid framework, you are relying on these straps to hold the weight of the stairs with nails instead of screws which will waggle loose with movement.

IM12DV8's profile picture
IM12DV84 months ago

No... because you are hanging weight carrying pieces from the support vs resting them on them. You're whole config is super stupid.

WeSpottedThem14Points's profile picture
WeSpottedThem14Points4 months ago

He's built so many then why is he confused? The stringers are cut wrong.

I agree with me's profile picture
I agree with me4 months ago

I don’t build decks and am not an engineer, but isn’t all the weight of those steps resist on those straps? Shouldn’t there be a support under those stringers that transfers the weight into 4x4 or 6x6 columns? This just looks way too shady for my untrained eye.

facts matter, lies shatter 🇳🇱 🇺🇸's profile picture
facts matter, lies shatter 🇳🇱 🇺🇸4 months ago

It's called redundancy. Don't cheap out on nails. It also triggers OCD. Also the wood looks split. I'm siding with the inspector.

@devonboy3410 🏴󠁧󠁢󠁥󠁮󠁧󠁿🏴󠁧's profile picture
@devonboy3410 🏴󠁧󠁢󠁥󠁮󠁧󠁿🏴󠁧4 months ago

Taking shortcuts on the safety specs is fine with this builder. I wouldn’t employ you with an “I don’t give a fuck” attitude. Yes, it’s only one nail, so why didn’t you do it? It’s 30 seconds of work.

Jon Demo's profile picture
Jon Demo4 months ago

And that nail has a chance of splitting the wood

Nick's profile picture
Nick4 months ago

Just put the fucking nail in there buddy

Kmorrill🟦⬜️🟩's profile picture
Kmorrill🟦⬜️🟩4 months ago

How you do anything, is how you do everything.

Jelly Bean Jerry's profile picture
Jelly Bean Jerry4 months ago

Its 2026. At this point everyone knows that things attached to your house has to be built by the book. Hes acting like they JUST made these rules.

sallad tattoos's profile picture
sallad tattoos4 months ago

why hole if no nail