Out door sub panel

167,880 просмотров • 3 месяцев назад •via X (Twitter)

Комментарии: 61

Фото профиля 𓐬 ✞ NoblePhares ✞ 𓐬
𓐬 ✞ NoblePhares ✞ 𓐬3 месяцев назад

I’ve never seen one of those heated pvc pipe benders before. Pretty sick. I can think of many past jobs where that tool would have been handy.

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

ohh that's really amazing I hope this tips can help it's clear for really

Фото профиля adam auger
adam auger3 месяцев назад

I have never understood the reason to put a breaker panel outside? Even if it is code in that area. Leaving anyone access to your breakers seems like a recipe for disaster. Can anyone tell me why they do this? I believe it is common in the southern US.

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

ohhh according to my experience maybe here's a security cameras can watch the person can make any unusual action

Фото профиля Sean Hurley
Sean Hurley3 месяцев назад

On today’s episode of: So you think you’re an electrician.

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

thank you

Фото профиля Steve Smith
Steve Smith3 месяцев назад

Steel pipe not plastic garbage and pipe straight into the bottom. Looks bad .

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

ok please share with us the best for you?

Фото профиля Steve Smith
Steve Smith3 месяцев назад

Like I said emt conduit straight i to the bottom for both. No plastic! Is that even schedule 80 pvc? And label the wires with phase tape.

Фото профиля American Man
American Man3 месяцев назад

Ring cuts wire , pvc glue on wire but he tourques to spec , my man

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

good suggestion

Фото профиля Mr.𝕏
Mr.𝕏3 месяцев назад

Terrible job, looks like garbage.

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

that's not terrible as you think

Фото профиля Mr.𝕏
Mr.𝕏3 месяцев назад

Ive seen worse. just not billed online as some magical process.

Фото профиля Lyndon Giles
Lyndon Giles3 месяцев назад

Only one issue. Knockout above buss bar without a water resistant connector. A PVC connector with a standard locknut is not considered an approved connection when above the buss bars.

Фото профиля Nate Abbott
Nate Abbott3 месяцев назад

Someone call ICE on this guy... he's trying to kill someone.. YOU DON'T BRING MEXICO TECHNOLOGY TO AMERICA !!

Фото профиля Bonafide Boomer
Bonafide Boomer3 месяцев назад

Sure, I want random people to have access to breaker box and just turn everything off. I want even get into the feed location that's been mentioned.

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

amazing

Фото профиля Jones Electric
Jones Electric3 месяцев назад

You just turned a 3R enclosure into an umbrella when you made that knockout above the terminal points dumb ass

Фото профиля Keith Hooker
Keith Hooker3 месяцев назад

Not very neat, sorry

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

that's best way you can use

Фото профиля Budcheeks
Budcheeks3 месяцев назад

That’s a shitty electrical contractor there. Anytime you enter an enclosure above the bus work do you not have to use a weatherproof hub? You might be able to find that in the NEC code book around 312.2.

Фото профиля New Hampshire Absolutist
New Hampshire Absolutist3 месяцев назад

I do not know why he went in the top. Seems dumb, get a bottom feed and bring the feeders in through the bottom. Pipe run looks like poop. I am So Glad i am a commercial guy, except clean rooms or wet washdown rooms, i never have to touch PVC.

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

ohh that's the only safety way that's why

Фото профиля MarcusK
MarcusK3 месяцев назад

that’s a work he was proud enough to show it online?

Фото профиля Jason Dodge
Jason Dodge3 месяцев назад

Never seen a circuit breaker box outside before.

Фото профиля Jerry Powers
Jerry Powers3 месяцев назад

Should have used an LL instead of an LB.

Фото профиля DatHandsomeJerk
DatHandsomeJerk3 месяцев назад

The mismatching conduit and elbow colors is lazy craftsmanship.

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

😂😂😂😂

Фото профиля Charles Tanner
Charles Tanner3 месяцев назад

The panel is inset to the wall not allowing for the drain holes to be in the open. Schedule 40 PVC ABOVE GRADE NOT PROTECTED. The side knocked out and not sealed with anything. Everything else looks great

Фото профиля EVEngineer
EVEngineer3 месяцев назад

Terminals done up with an impact driver 🤣 why is the panel outside ?

Фото профиля Eugene
Eugene3 месяцев назад

Они какой-то кайф испытывают, так коротко обрезая провода, не оставляют никакого запаса. А вдруг фазы перекинуть местами нужно будет

Фото профиля Earl 🇺🇸🇺🇸🇺🇸
Earl 🇺🇸🇺🇸🇺🇸3 месяцев назад

That’s a main panel not a sub panel. You only put a ground rod on the main service

Фото профиля George Sawision ME
George Sawision ME3 месяцев назад

Never did use aluminum feeder wires! But much cheaper

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

yeah bcz aluminum is not good conduct of heat

Фото профиля George Sawision ME
George Sawision ME3 месяцев назад

Aluminum has to be treated properly to ensure the connection doesn't corrode and become a fire hazard. I have seen many connections that burned because of the wire connection not being done properly

Фото профиля Eli Olson
Eli Olson3 месяцев назад

Not a sub panel. The ground and neutral appear to be bonded

Фото профиля Chief
Chief3 месяцев назад

I need to get me one of those torque flat tips! Would save me a trip to the truck everyday!

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

yeah I'm here to support you don't worry

Фото профиля Chief
Chief3 месяцев назад

I couldn't tell for sure but it looked like grounds and neutrals were separated.

Фото профиля Kenny5Alive
Kenny5Alive3 месяцев назад

Why the LB?

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

I hope you're satisfied?

Фото профиля Covfefe is for Closers ☕️
Covfefe is for Closers ☕️3 месяцев назад

Be by in a few minutes to switch off a couple of these breakers

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

🤔🤔

Фото профиля mary folkerts
mary folkerts3 месяцев назад

A lot of skill goes into this work thanks for the great job

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

you're welcome my dear

Фото профиля Stapes
Stapes3 месяцев назад

American electrical installation is absolutely trash, more like plumbing

Фото профиля Artdept
Artdept3 месяцев назад

Nice work

Фото профиля Gorzeskol
Gorzeskol3 месяцев назад

Horrible... In Mexico we have bad installations but we never use PVC for an electrical environment, PVC suffered heat deformation and reacted very badly to fire. Electrical Metal Conduit is way better

Фото профиля 🇺🇲 Silly Relic 🇺🇸
🇺🇲 Silly Relic 🇺🇸3 месяцев назад

Never replaceable with AI

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

that's not Ai please

Фото профиля Jason Ellison
Jason Ellison3 месяцев назад

Why is the panel outside?

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

for preventing Electricity risk

Фото профиля Jason Ellison
Jason Ellison3 месяцев назад

Na if you need a emergency shut off just put a disconnect outside. Not the whole panel

Фото профиля vladROBOT🪱
vladROBOT🪱3 месяцев назад

… and up to $240,000.00 per annum. Whoa❗️

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

that's amazing

Фото профиля vladROBOT🪱
vladROBOT🪱3 месяцев назад

It is isn’t it.

Фото профиля Joseph Gaydosh
Joseph Gaydosh3 месяцев назад

Don’t miss electrical work AT ALL

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

yeah great idea

Фото профиля JoHo
JoHo3 месяцев назад

Still using deox on aluminum alloy I see.

Фото профиля Biochar in Agriculture
Biochar in Agriculture3 месяцев назад

yeah good