What do you think about deployment depth? Good enough or too deep. Mild PVL.

18,809 görüntüleme • 1 yıl önce •via X (Twitter)

11 Yorum

Abdel Almanfi, MD, FACC, FSCAI profil fotoğrafı
Abdel Almanfi, MD, FACC, FSCAI1 yıl önce

Yes it’s deeper than where it should but apparently with no major consequences! Pay attention to your catheter positioning in relation to ascending aorta, try to be central (coaxial) to avoid canting. Use cusp overlap or near cusp overlap if bicuspid.

Dr Imran Hanif Hashmi profil fotoğrafı
Dr Imran Hanif Hashmi1 yıl önce

Thank you for your valuable comments. Recaptured twice and then deployed. Constrained even after post-dil. There was AVD. Resolved in a couple of days. PPM was not required.

AshishShah profil fotoğrafı
AshishShah1 yıl önce

Valve looks slightly lower than ideal position. Was this a bicuspid AV? Do you have an orthogonal view of the valve post deployment? Thanks.

Dr Imran Hanif Hashmi profil fotoğrafı
Dr Imran Hanif Hashmi1 yıl önce

Not a true bicuspid but an Acquired bicuspid calcified fusion of NCC and RCC. Yes, I think the same looks slightly deep.

K Spargias profil fotoğrafı
K Spargias1 yıl önce

Not only deep but also compressed at its waist. Valvuloplasty balloon kept dog-boned and underexpanded and remaining restrained bicuspid anatomy pushed down to this positioning and valve waist compression

Joe Aoun profil fotoğrafı
Joe Aoun1 yıl önce

It is deep but mild PVL and no ppm, this is a win and it will help with future TAV in TAV, if needed. What balloon did you use for pre and post ballon dilation? It is interesting how the pre balloon did not expand all the way. Any gradient post implant?

Dr Imran Hanif Hashmi profil fotoğrafı
Dr Imran Hanif Hashmi1 yıl önce

22mm NC for predil. 25mm NC for post dil. 29mm evolut. Less than 5mm gradient postprocdure.

Saeed Tarabichi, MD profil fotoğrafı
Saeed Tarabichi, MD1 yıl önce

Seems very deep especially towards the left cusp. Any pacemaker needs?

Dr Imran Hanif Hashmi profil fotoğrafı
Dr Imran Hanif Hashmi1 yıl önce

There was AVD post-procedure. Resolved in a couple of days. PPM was not required.

Ganesh Muthappan profil fotoğrafı
Ganesh Muthappan1 yıl önce

Deep but result looks fine. If conduction system is ok then it’s a win.

Dr Imran Hanif Hashmi profil fotoğrafı
Dr Imran Hanif Hashmi1 yıl önce

Yes. AVD in early post-op days but resolved in a couple of days. PPM wasn't needed.