Why Pumps CANNOT Suck Water Deeper Than 10.3 Meters! (Physics Explains)

155,061 görüntüleme • 1 ay önce •via X (Twitter)

18 Yorum

Donald O'Connor profil fotoğrafı
Donald O'Connor1 ay önce

Impeller is spinning the wrong direction for that volute

Ted Roberts profil fotoğrafı
Ted Roberts1 ay önce

That is why the pump is underground on the end of the pipe in the water table. Every well I know of is beyond 10 meters or 30 feet where it draws up water

De Pan profil fotoğrafı
De Pan1 ay önce

Nah.. diapragh and piston pump can suck water deeper. Volume type pump

Ultra Derek profil fotoğrafı
Ultra Derek1 ay önce

Is it me or is that pump designed wrong.

Vergil Arcanis profil fotoğrafı
Vergil Arcanis1 ay önce

That's why you push, dipshit. The pumps are normally in the basement/lowest level, with potetial staging pumps if it is calculated to be too much every rise

LbTrucker profil fotoğrafı
LbTrucker1 ay önce

Total brainwashing bs.

Thought i'd change my name profil fotoğrafı
Thought i'd change my name1 ay önce

Have scientists spoken to Bonnie Blue?

Best Hunter in the entire galaxy profil fotoğrafı
Best Hunter in the entire galaxy1 ay önce

No thats not right I have a well and I have an above ground pump the top of the water in the well is 40'

FEDUP profil fotoğrafı
FEDUP1 ay önce

@NovaNova266079 Poppycock. My surface pump is over 16m

Tshimuga-Ramafatha🇿🇦 profil fotoğrafı
Tshimuga-Ramafatha🇿🇦1 ay önce

Had this problem and pump burned the windings when im on holiday and no one primming the pump to suck water out... Replaced the pump and installed an sensor operated solenoid valve to run in parrallel with pump ON switching for limitted time... its now a wifi smart system

483212 🇬🇧🇦🇺 profil fotoğrafı
483212 🇬🇧🇦🇺1 ay önce

Inject air and push the water back up. Works for oil well restarts.

US Patriot profil fotoğrafı
US Patriot1 ay önce

Different pumps for different applications

suresh profil fotoğrafı
suresh1 ay önce

Education

Leon Mandrake profil fotoğrafı
Leon Mandrake1 ay önce

Make a deep groin well, like the ancient one, put it at your 10.3m deep , and pull that water from reserve

Wochnisz profil fotoğrafı
Wochnisz1 ay önce

Nie tłoczyć ale zasysać. Tłoczyć mogą na dowolną wysokość - woda w kranie na 40 piętrze wieżowca.

Kari Noren profil fotoğrafı
Kari Noren1 ay önce

Just drop the pump head under the water.

FIGHT FIGHT FIGHT!! profil fotoğrafı
FIGHT FIGHT FIGHT!!1 ay önce

Submersible

Butters_Actual profil fotoğrafı
Butters_Actual1 ay önce

Bullshit. I personally installed the 80ft of downhole plumbing and above ground pump for a water well that worked for years This video is full of pure shit.