Video wird geladen...

Video konnte nicht geladen werden

Zur Startseite

566,658 Aufrufe • vor 1 Monat •via X (Twitter)

34 Kommentare

Profilbild von Miroslav Joksimović
Miroslav Joksimovićvor 1 Monat

When you have enough experience, passthrough RJ45s are pointless. Only for beginners.

Profilbild von William Clark
William Clarkvor 1 Monat

If you had skills, you don’t need expensive pass-through connectors.

Profilbild von DogManDan
DogManDanvor 1 Monat

No passthroughs were harmed in the making of the real network room rack. In my 30+ years of networking I have never and will never use a passthrough piece of junk.

Profilbild von Dan 𝙏𝙖𝙭𝙖𝙩𝙞𝙤𝙣 𝙄𝙨 𝙏𝙝𝙚𝙛𝙩 Behrman Esq🍍
Dan 𝙏𝙖𝙭𝙖𝙩𝙞𝙤𝙣 𝙄𝙨 𝙏𝙝𝙚𝙛𝙩 Behrman Esq🍍vor 1 Monat

If you don't practice the real way you're never going to learn. This is like training wheels. And they don't work with regular crimpers.

Profilbild von PoliTech 🇺🇲
PoliTech 🇺🇲vor 1 Monat

Back when I was an IT contractor in the late 90s, I tried to explain to a tokin ring network engineer that he had to maintain the twist on RJ45 ethernet connections when punching down terminals. He was untwisting about a foot of each wire and punching them into the female connector, then wrapping the excess around his hand and stuffing if all back into the ethernet receptical wall housing. I explained about EMI/RFI and how the twist maintains the magnetic field to resist EMI to get maximum throughput. He made fun of me in a meeting, saying that I warned him about "waves in the air". He then advised going back to Coaxial Tokin Bus and tokin ring because 100 mbps ethernet only really had 1 maps throughput. 😏 I left that gig, and went o work somewhere else.

Profilbild von Scot Beaird
Scot Beairdvor 1 Monat

I hate the pass-thru connectors. Only for the weak!

Profilbild von WJP
WJPvor 1 Monat

The pass-through RJ45 is the clip-on tie of the IT world.

Profilbild von Tim Sonner
Tim Sonnervor 1 Monat

Huge fan of pass through. 2 things stick out in this demo. Using the sheath to untwist the wires and cutting the wires at an angle. I’ll have to try those next time I terminate a cable.

Profilbild von Philip 🇺🇸
Philip 🇺🇸vor 1 Monat

That was horrible

Profilbild von 🩶🤍🖤🤎❤️🧡💛💚💙💜
🩶🤍🖤🤎❤️🧡💛💚💙💜vor 1 Monat

not a single one in the comment gives a reason why they hate passthrough connectors.

Profilbild von Delayed-Neutrons
Delayed-Neutronsvor 1 Monat

Had no idea these existed, thanks!

Profilbild von Protect The 2nd
Protect The 2ndvor 1 Monat

I've crimped THOUSANDS of RJ45's without passthrough and NEVER had one as horrible as shown! That's intentional slop to sell a product that isn't needed! I bought a pass-through recently to try it. It's actually HARDER because the wires have to be just right to fit under the cutter!

Profilbild von Elgorynne
Elgorynnevor 1 Monat

I solder my cables directly onto my motherboard. Best way to do things.

Profilbild von Face Palm is the new Face Book
Face Palm is the new Face Bookvor 1 Monat

I have made some really clean non passthrough ones. You have to cut the cables dead perpendicular and at the right length. It's not hard

Profilbild von The_Redworm
The_Redwormvor 1 Monat

Standard is easy with a little practice. Pass-throug leaves you prone to shorts and emf int. Its for ametures.

Profilbild von The Ghost in the Machine that you rage against
The Ghost in the Machine that you rage againstvor 1 Monat

Or you could use keystones into a patch panel and pre-made patch cables into the switch

Profilbild von grumplestiltzkin
grumplestiltzkinvor 1 Monat

this was the most painful tipping I've seen in over 20 years. Yeah, if you have 3 inches of individual wires, it can look like that. After the first few, you get an idea of how long to make them. The passedthrough wire can prevent seating or cause premature failure that just doesn't happen with standard connectors. Who is unravelling twisted pairs like that? 1.5/10 stars - probably failed CCNA *and* network+

Profilbild von Dark
Darkvor 1 Monat

EZ-RJ (passthrough) connectors are the worst. When the blade on the tool gets a little dull, it leaves a short stubs on the wire. Those stubs prevent the connectors from seating correctly in switches and can easily short together which causes all kinds of problems. Fuck EZ-RJs.

Profilbild von JulioBG.
JulioBG.vor 1 Monat

Estos son los chidos.

Profilbild von WTF
WTFvor 1 Monat

Ok. These guys are so dramatic in these videos... 😂 Nobody does or let someone do that; if so, he's a Uber driver right now... Yes. Pass through Rj45 is a thing.

Profilbild von 🪓 🦋
🪓 🦋vor 1 Monat

Avoid router usage.

Profilbild von Russell Johnson
Russell Johnsonvor 1 Monat

There’s a large following that acts like this is a cardinal sin that will short ever switch you could think of using. In reality it’s more convenient and faster, if you have a real concern of a short due to moisture put some dielectric grease on it.

Profilbild von Freedom45
Freedom45vor 1 Monat

Be carefull pass thru means something else in networking. Modern switches hand that kind of pass thru. Unrelated, snagless so much better.

Profilbild von CronoT80
CronoT80vor 1 Monat

Those kind of RJ45 tips are a really shitty design. They let in moisture & can cause rusting & swelling, damaging the wires & the conducting contacts inside the tip.

Profilbild von Alext
Alextvor 1 Monat

No. That's bad

Profilbild von Mike Wheeler
Mike Wheelervor 1 Monat

💯

Profilbild von Sergey Bodrov
Sergey Bodrovvor 1 Monat

Disgusting!

Profilbild von Peach
Peachvor 1 Monat

For the most part pass through seem to be a solution for a minimal problem, just learn to do it properly, the "alternative" example is just atrocious

Profilbild von Georider19
Georider19vor 1 Monat

Passthroug is good for CAT6E and CAT7 cable , they are so hard to move and connect

Profilbild von Make My Day
Make My Dayvor 1 Monat

Dang, and I been throwing them all away. Is that Rick James music by the way?

Profilbild von Justin Randall
Justin Randallvor 1 Monat

Use the ones with the internal sled instead of pass through. Same idea but the copper tips of the wires aren’t exposed afterwards.

Profilbild von Dunewolf
Dunewolfvor 1 Monat

That middle bit? yeah I like to pull up on that before cutting it.. so it goes back below the end.. helps allow for better connection when shoving them through pass thru RJ45 ends.. get bit more outer cover under the crimp that helps hold the jacket.. also - No boot? oof.

Profilbild von Diaghilev'sGhost
Diaghilev'sGhostvor 1 Monat

I always forget to put on the connector cover too.

Profilbild von skiminok Quail
skiminok Quailvor 1 Monat

Дикое расточительство! Так много лишнего провода отрезается😱

Ähnliche Videos